Mfg Part Number: R10-1011 | Alternate P/N: R101011 |
NSN : 5985-01-376-3607 | NIIN : 013763607 |
CAGE Code : 06351 | Manufacturer: Microwave Engineering Corporation |
Item Name : Waveguide Assembly | FSC : 5985 Antennas Waveguides and Related Equipment |
Thank you for your interest in the NSN part R10-1011. This item was manufactured by Microwave Engineering Corporation and is a Waveguide Assembly component with the NSN 5985-01-376-3607. This R10-1011 is available for immediate purchase, and we would be happy to provide you with a quick quotation for your comparisons. To begin, please fill out and submit an Instant RFQ form provided on this page. After receiving your request, an account manager will immediately start crafting a competitive quote that reflects your individual requirements.
Stacked Purchasing offers R10-1011 with various CAGE Code 06351 parts from Microwave Engineering Corporation, one of the manufacturers on our thoroughly vetted approved vendor list. Whether it is 5985-01-376-3607 or any other component that we distribute, we stand by the quality of our products. Stacked Purchasing operates with AS9120B, ISO 9001:2015, and FAA AC 00-56B certification and accreditation, and we have an unmatched dedication to providing our customers with the best possible parts. Moreover, our team members take the time to identify customers' exact time requirements, and with our vast distribution network, we are agile in our shipping execution. Please get in touch with our team if you want to learn more about our services. We look forward to being your strategic sourcing partner.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-376-3607 Item Description: Waveguide Assembly | 5985 | 013763607 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R10-1011 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR" |
AAJD | THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES" |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES" |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT" |
AHSF | FLANGE QUANTITY | 2" |
AHSX | FLANGE INSIDE WIDTH | 0.795 INCHES MINIMUM ALL FLANGES AND 0.801 INCHES MAXIMUM ALL FLANGES" |
AHSY | FLANGE INSIDE HEIGHT | 0.425 INCHES MINIMUM ALL FLANGES AND 0.431 INCHES MAXIMUM ALL FLANGES" |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES" |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES" |
AHTD | FLANGE DEPTH | 0.250 INCHES NOMINAL ALL FLANGES" |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.35" |
AHTX | INSERTION LOSS IN DECIBELS | 0.50" |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL FLANGES ALL CONNECTION FACILITIES" |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.691 INCHES NOMINAL" |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.321 INCHES NOMINAL" |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL" |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 CAPTIVE SCREWS ALL FLANGES ALL CONNECTION FACILITIES" |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES" |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 6.180 INCHES MINIMUM AND 6.440 INCHES MAXIMUM" |
CXBD | WAVEGUIDE HEIGHT | 5.620 INCHES MINIMUM AND 5.880 INCHES MAXIMUM" |
FLEX | FLEXIBILITY | FLEXIBLE ALL TUBING SEGMENT OR RIGID ALL TUBING SEGMENT" |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT" |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT ALL SURFACES" |
STYL | III STYLE DESIGNATOR | DOUBLE BEND TYPE" |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES" |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR" |
AAJD | THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES" |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES" |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT" |
AHSF | FLANGE QUANTITY | 2" |
AHSX | FLANGE INSIDE WIDTH | 0.795 INCHES MINIMUM ALL FLANGES AND 0.801 INCHES MAXIMUM ALL FLANGES" |
AHSY | FLANGE INSIDE HEIGHT | 0.425 INCHES MINIMUM ALL FLANGES AND 0.431 INCHES MAXIMUM ALL FLANGES" |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES" |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES" |
AHTD | FLANGE DEPTH | 0.250 INCHES NOMINAL ALL FLANGES" |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.35" |
AHTX | INSERTION LOSS IN DECIBELS | 0.50" |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL FLANGES ALL CONNECTION FACILITIES" |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.691 INCHES NOMINAL" |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.321 INCHES NOMINAL" |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL" |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 CAPTIVE SCREWS ALL FLANGES ALL CONNECTION FACILITIES" |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES" |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 6.180 INCHES MINIMUM AND 6.440 INCHES MAXIMUM" |
CXBD | WAVEGUIDE HEIGHT | 5.620 INCHES MINIMUM AND 5.880 INCHES MAXIMUM" |
FLEX | FLEXIBILITY | FLEXIBLE ALL TUBING SEGMENT OR RIGID ALL TUBING SEGMENT" |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT" |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT ALL SURFACES" |
STYL | III STYLE DESIGNATOR | DOUBLE BEND TYPE" |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote